Perbedaan Kualitas Citra MRI Pelvis Pada Kasus Kanker Prostat dengan Variasi B Value Di Instalasi Radiologi RSUP Prof. Dr. I.G.N.G Ngoerah

Authors

  • Luh Eka Aza Pratiwi Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • I Made Lana Prasetya Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • I Putu Sugiartha Akademi Teknik Radiodiagnostik dan Radioterapi Bali

DOI:

https://doi.org/10.59680/ventilator.v1i4.673

Keywords:

B value, Prostate cancer, SNR, CNR

Abstract

B value is a factor that reflects the strength and timing of the gradient that will be used to generate a diffusion-weighted image. The higher the b value, the stronger the effect on diffusion. B value can be expressed in units of s/mm2 with a b value range of 500 s/mm2 to 1500 s/mm2. The use of b value in Diffusion Weighted Imaging (DWI) sequences is very important in detecting prostate cancer to distinguish malignant and benign cancer tissue because b value determines the amount of diffusion weighting and shows the sensitivity of the sequence to diffusion. The purpose of this study is to determine the difference in the quality of SNR and CNR images with b value variations in Pelvic MRI examination in prostate cancer cases. This study uses quantitative research methods with an experimental approach. The study population and samples were 4 Pelvic MRI patients with prostate cancer cases who underwent examination in July-August 2023 at the Radiology Installation of Prof.Dr.I.G.N.G Ngoerah Hospital, and each sample was subjected to b value variations of 800, 1000, 1400 and 2000 on the Diffusion Weighted Imaging (DWI) sequence. Data were processed using radiant DICOM and then analyzed using normality test and repeated anova test on SPSS 25 software. The results showed a significance value (p-value) > than 0.05, it can be concluded that H0 is accepted and Ha is rejected, which means that there is no difference in Pelvic MRI image quality in Prostate Cancer Cases with b value variations. The b value variation of 800 on Pelvic MRI examination on Diffusion Weighted Imaging (DWI) sequences with prostate cancer cases can produce more optimal image quality compared to b value variations of 1000, 1400 and 2000.

References

Abou khadrah, R. S., & Imam, H. H. (2019). Multiple b values of diffusion-weighted magnetic resonance imaging in evaluation of solid head and neck masses. Egyptian Journal of Radiology and Nuclear Medicine, 50(1). https://doi.org/10.1186/s43055-019-0054-3

Daniswara, C. L. (2020). Pencitraan Kanker Prostat. Cdk-283.

Ernandi, F. N., & . M. (2020). ANALISIS VARIASI a-VALUE DAN b-VALUE DENGAN MENGGUNAKAN SOFTWARE ZMAP V.6 SEBAGAI INDIKATOR POTENSI GEMPA BUMI DI WILAYAH NUSA TENGGARA BARAT. Inovasi Fisika Indonesia, 9(3), 24–30. https://doi.org/10.26740/ifi.v9n3.p24-30

Kartikasari, Y., Kartili, M. I., Rochmayanti, D., & Aprilia, N. (2020). Perbedaan Informasi Citra Anatomi Sekuen Diffusion Weighted Imaging (Dwi) Antara Penggunaan Propeller Dengan Tanpa Propeller Pada Pemeriksaan Mri Brain Dengan Kasus Stroke. Jurnal Imejing Diagnostik (JImeD), 6(1), 36–43. https://doi.org/10.31983/jimed.v6i1.5565

Knipe, H., & Morgan, M. (2015). Pi-Rads. Radiopaedia.Org. https://doi.org/10.53347/rid-32465

Nizar, S., Fatimah, F., & Kartili, I. (2019). Pengaruh Variasi Time Repetition (Tr) Terhadap Kualitas Citradan Informasi Citra Pada Pemeriksaan Mri Lumbalsekuens T2 Fse Potongan Sagital. Jurnal Imejing Diagnostik (JImeD), 5(2), 89. https://doi.org/10.31983/jimed.v5i2.4473

Noor, F. N. (2021). PERANAN SEKUEN DIFFUSION WEIGHTED IMAGING (DWI) PADA PEMERIKSAAN MRI BRAIN UNTUK DIFERENSIASI MENINGIOMA. http://repository.poltekkes-smg.ac.id/index.php?p=show_detail&id=23695&keywords=

Pramanda NA. (2015). PENGARUH VARIASI "b" VALUE DWI TERHADAP KUALITAS CITRA MRI PELVIS PADA PASIEN KANKER SERVIKS DI RUMAH SAKIT PUSAT KANKER DHARMAIS. Available at : https://perpus.poltekkesjkt2.ac.id/respoy/index.php?p=show detail&i d=3138&keywords=

Sangadji, N. W., Ayu, I. M., & Epid, M. (2018). EPIDEMIOLOGI PENYAKIT TIDAK MENULAR ( PTM ) EPIDEMIOLOGI PENYAKIT Jantung Koroner Tahun 2018. 1(3), 5–6.

Setya Putri, S., Katili, M. I., Prastanti, A. D., & Putri, S. S. (2019). Analisis Citra MRI Teknik DWI (Diffusion Weighted Imaging) dengan Variasi Nilai “b” Value Pemeriksaan MRI Brain Kasus Stroke Iskemik Hiperakut. 2005, 1–6.

Westbrook, C. (2014). Handbook Of MRI Technique Fourth Editional.

Downloads

Published

2023-10-16

How to Cite

Luh Eka Aza Pratiwi, I Made Lana Prasetya, & I Putu Sugiartha. (2023). Perbedaan Kualitas Citra MRI Pelvis Pada Kasus Kanker Prostat dengan Variasi B Value Di Instalasi Radiologi RSUP Prof. Dr. I.G.N.G Ngoerah. Jurnal Ventilator, 1(4), 86–97. https://doi.org/10.59680/ventilator.v1i4.673

Similar Articles

You may also start an advanced similarity search for this article.