Perbandingan Nilai Metabolik Pada Mr-Spectroscopy Dengan Dan Tanpa Media Kontras Di Rsup Persahabatan Jakarta Timur

Authors

  • Ici Zuhra Wulandari Sekedang AKTEK Radiodiagnostik dan Radioterapi Bali
  • I Putu Eka Juliantara AKTEK Radiodiagnostik dan Radioterapi Bali
  • I Bagus Gede Dharmawan AKTEK Radiodiagnostik dan Radioterapi Bali

DOI:

https://doi.org/10.59680/ventilator.v1i4.664

Keywords:

Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, post-contrast, pre-contrast, multi- voxel

Abstract

Comparison Of Metabolic Value On MR-Spectroscopy With and Without Contrast Media at Persahabatan Hospital, East Jakarta.

Magnetic Resonance Spectroscopy is a non-invasive technique that can be used to measure the metabolism of several biochemical components in body tissue, especially the brain. Based on observations made by the author at Persahabatan Hospital, the spectroscopy technique used at Persahabatan Hospital is a multi-voxle technique, with sequences selction namely s2D_PRESS_144, where the spectroscopy images are taken after administering contrast and prevalence for tumor cases in the Radiology Installation at Persahabatan Hospital, with 5 data from the month May-August 2023. To determine the validity of this opinion, the authors performed pre and post- contrast MR-Spectroscopy on patients with contrast and compared the results with patients without contrast. In this study the author used a quantitative analysis type of research with an experimental approach aimed at whether the administration of contrast material affects the results of MR-Spectroscopy in patients with brain tumor cases. Where the research data comes from primary data in the Radiology installation at Persahabatan Hospital from May - August 2023 using 5 patient data. Results: Based on an observational study carried out on primary data from 5 patients, there were differences in metabolic values with and without contrast media in brain tumor cases. And MR-Spectroscopy examination without contrast is better to use than with contrast, although from the overall data it turns out there are some data that say post- contrast is higher.

References

Bhimani A, Bhimani A, Charles, Horngren T, Datar SM, Madhav, Rajan V. Seventh Edition [Internet]. 2018. Available from:www.pearson-books.com.

Khairuzzaman MQ. Gambaran Gangguan Fungsi Kognitif Pada Tumor Otak Primer dan Metastasis. 2016;4(1):64–75. DIM, Ngelis E a. B Rain TUmors. Med Prog N Engl J Med. 2001;114(2):114– 23.

Comelli I, Lippi G, Campana V, Servadei F, Cervellin G. Clinical presentation and epidemiology of brain tumors firstly diagnosed in adults in the Emergency Department: A 10-year, single center retrospective study. Ann Transl Med. 2017;5 (13):3–7.

Akkus Z, Galimzianova A, Hoogi A, Rubin DL, Erickson BJ. Deep Learning for BrainMRI Segmentation: State of the Art and Future Directions. J Digit Imaging. 2017;30(4):449–59.

Smith JK, Kwock L, Castillo M. Effects of contrast material on single-volume proton MR spectroscopy. Am J Neuroradiol. 2000;21(6): 1084–9.

Sasmito AP, Abimanyu B, Prasanti AD. Prosedur Pemeriksaan Magnetic Resonance Spectroscopy (Mrs) Kepala Pada Kasus Epilepsi Di Instalasi Radiologi Rsup Dr. Kariadi Semarang. 2022.

Lin NU, Winer EP. Brain metastases: The HER2 paradigm. Clin Cancer Res. 2007; 13 (6):1648–55.

Rees JH. Diagnosis and Treatment In Neuro-oncology: An oncological perspective. Br J Radiol. 2011;84 (SPEC. ISSUE 2).

Mulyono N, Susy S. Pemanfaatan Magnetic Resonance (MRI) Sebagai Sarana Diagnostik Pasien. [Internet]. 2004.p.8–13. Available from: https:doi.org/10.1111/j.19397445.2010.00082.x.

Brier J, lia dwi jayanti. Fifth edition MRI Basic Principle and applications Vol. 21. 2020.

Moshinsky M. Handbook of MRI Technique Fouth Edition . Vol. 13, Nucl. Phys. 1959. 104–116 p.

Catherine Westbrook. Handbook of MRI Technique. Wiley- Blackwell. 2008. 424 p.

Ray Hashman Hashemi, M.D., Ph.D.;William G. Bradley Jr, M.D., Ph.D., F.A.C.R.;Christopher J. Lisanti, M.D., Col. (ret) USAF, MC S. The Basics MRI.2013. 395p.

Drost DJ, Riddle WR, Clarke GD. Proton magnetic resonance spectroscopy in brain: Report of AAPM MR Task Group #9. Med Phys. 2002;29(9):2177– 97.

Fajarini, Eunike Serfina, dkk. MRI ITU CRUNCHY!. 2011.

Kousi E, Tsougos I, Vasiou K, Theodorou K, Poultsidi A, Fezoulidis I, et al. Magnetic resonance spectroscopy of the breast at 3T: Pre- and post- contrast evaluation for breast lesion characterization. Sci World J. 2012;2012.